Shop By Categories
Powtran 75 HP 55 kW Threephase (3x380) VFD solar pumping inverters

Powtran 75 HP 55 kW Threephase (3x380) VFD solar pumping inverters

Brand:Powtran
Product Code: PI500A-S 055G3
Reward Points: 980
SKU : Powtran 55Kw PV
Product available in stock : 1
  • 39,631.20₺

  • Ex Tax: 33,026.00₺
  • Price in reward points: 98000
  • 10 or more 38,418.00₺
  • 100 or more 35,991.60₺

Available Options


The products can be delivered from the factory, Ankara or Istanbul branch. If you are close to the branches of our company, you can check the stock in our unit close to you by contacting us by phone or e-mail.
Shippment Fee :You can order or order shipping cost. Those who cannot get cheap money from our company.
Dimension 500km 750km1000km+++
Box-Shippment1day2 day 3 day5 day
By Truck3 day 4 day 5 day
7 day
  • Easy to buy & return
  • 100% Secure Payments
  • 24x7 Support Available
  • Shop with our Application

Tags: 55 kw powtran, powtran Solar motor driver, 75HP motor driver, 55kw motor driver

Taksit Tutarı
Toplam Tutar
2 x 15.862,40 TL
31.724,80 TL
3 x 10.818,01 TL
32.454,03 TL
4 x 8.303,46 TL
33.213,85 TL
5 x 6.807,48 TL
34.037,42 TL
6 x 5.808,94 TL
34.853,65 TL
Taksit Tutarı
Toplam Tutar
2 x 15.879,39 TL
31.758,78 TL
3 x 10.834,61 TL
32.503,84 TL
4 x 8.322,11 TL
33.288,42 TL
5 x 6.826,29 TL
34.131,46 TL
6 x 5.829,50 TL
34.977,00 TL
Taksit Tutarı
Toplam Tutar
2 x 15.869,20 TL
31.738,39 TL
3 x 10.845,31 TL
32.535,94 TL
4 x 8.335,21 TL
33.340,83 TL
5 x 6.838,89 TL
34.194,44 TL
6 x 5.845,36 TL
35.072,16 TL
Taksit Tutarı
Toplam Tutar
2 x 15.852,23 TL
31.704,45 TL
3 x 10.810,91 TL
32.432,73 TL
4 x 8.297,89 TL
33.191,54 TL
5 x 6.802,80 TL
34.014,00 TL
6 x 5.804,85 TL
34.829,08 TL
Taksit Tutarı
Toplam Tutar
2 x 16.044,37 TL
32.088,74 TL
3 x 11.019,44 TL
33.058,31 TL
4 x 8.526,98 TL
34.107,90 TL
5 x 7.036,91 TL
35.184,53 TL
6 x 6.073,08 TL
36.438,49 TL
Taksit Tutarı
Toplam Tutar
2 x 15.976,94 TL
31.953,87 TL
3 x 10.900,33 TL
32.701,00 TL
4 x 8.367,20 TL
33.468,79 TL
5 x 6.853,91 TL
34.269,53 TL
6 x 5.847,44 TL
35.084,61 TL
Taksit Tutarı
Toplam Tutar
2 x 16.037,43 TL
32.074,86 TL
3 x 10.968,08 TL
32.904,23 TL
4 x 8.446,33 TL
33.785,32 TL
5 x 6.959,28 TL
34.796,39 TL
6 x 5.954,53 TL
35.727,20 TL
Taksit Tutarı
Toplam Tutar
2 x 15.842,06 TL
31.684,12 TL
3 x 10.806,18 TL
32.418,54 TL
4 x 8.298,81 TL
33.195,25 TL
5 x 6.804,36 TL
34.021,80 TL
6 x 5.808,94 TL
34.853,65 TL
Taksit Tutarı
Toplam Tutar
2 x 15.893,01 TL
31.786,02 TL
3 x 10.853,65 TL
32.560,95 TL
4 x 8.342,71 TL
33.370,85 TL
5 x 6.836,52 TL
34.182,61 TL
6 x 5.838,45 TL
35.030,72 TL

WARNING &Installation

1 Installation environment

- No Water drops, steam, dust or oily dust surrounded

- No caustic or inflammable gas and liquid surrounded

- No floating dust and metal particles surrounded

- Solid base without vibration

 - No electromagnetic or noise interference

 - Ambient temperature should be -10°C ~ +50°C; in case that the ambient temperature is higher than 40°C and that it is overheated, it should be stored in a place where there is good ventilation

2-Installation Instructions and Space Limit

 -It should be installed on the fire-proof frame, for example metal frame, in case that it causes fire accidents

 -It should be mounted by screws vertically; upside-down, slant or horizontal mounting are not allowed

 -Spare space must be ensured for the ventilation of converter in case that it's overheated while it's running

 -Ventilation must be taken into consideration to ensure that ambient temperature is lower than specified value when converter is installed inside a control cabinet

 -To minimize the heat effect on each other, they should be horizontally installed abreast if two or more converters are installed in the same control cabinet; Baffle plate must be set up between them for the same reason if they have to be installed vertically

 -It should be kept away from various impurity, such as fiber, paper scraps, wood chips or metal filing

- PE earth terminal must be connected with the ground

- The rated voltage must be in conformity with AC voltage

 -Power cords must be connected with the terminal R, S and T while lines for motor should beconnected with terminal U,V and W; any incorrect connection may cause damage to the internalcomponents of converter

 -The reliability of the terminals and wires must be evaluated before wiring, and screws for theterminals of major loop must be fastened solidly.

To avoid electric shock, do not touch the terminals of major loop

1 Connection of input terminal R, S, T or L, N

An additional breaker/chopper must be connected in series with the terminals of major loop(R,S,T or L,N) and three-phase AC or Single-phase AC input. For better running, an electromagnetic contactor should be connected with them in series so that it could cut off the power while the protection function of converter is activated (Tip: R-C surge absorbers should be added to the ends of electromagnetic contactor.

If an additional

earth leakage circuit breaker (ELCB) is installed as a protective device for electric leakage , the sensitivity of current should be more than 200mA while actuation time should be no less than 0.1 second in order to prevent ELCB from ma l function ing.

AC reactor must be connected with the input terminals in case that some of rectifiers are damaged by high voltage and high current input circuit from the grid , which could also improve the power factors of input terminals.

Do not control the converter by adopting the wa y of powering on or off major loop. Instead of that, RUN/STOP buttons on the keyboard or control loop terminals should be applied to the control of converter; if it has to be controlled by that way, it can be implemented only once every one hour.

It's feas ible to reduce the interference with devices nearby by connecting an additional noise filter with the input terminals.

Do not connect converter driven by three phase power to single phase source.

Powtran Motor Sürücü
Features

Benefits
Support Maximum MPPT %99 Efficen.
485 communication, SPI, GPRS, PG
Solar MPPT mode and  PID mode
Support IM, PM, hybrid AC DC mode 

Support PV ,AC grid input together


Support full water and low water P.
Support remote monitoring online GPRS
Three Phase, mono Phase ,Sine Wave

AC Out Power Range
DC Bus Bar Voltage Range
Frequency
0.37KW-375Kw
150V-440V
1HZ-3000Hz
GTIP Custom Code :8504409999 Manufacturer  
Powtran PI500-S series inverter special for PV water pump adopts the high accuracy fast MPPT algorithms, tracking the PV array output by the maximum power point, driving the pump motor as much as possible to meet various pumping applications.
Powtran technology(Dalian Powtran Technology Co.,Ltd.)is a high-tech Enterprise integrating the research and development, production, logistics and service of the motor control intelligent products and complete sets. In 1984, Toshiba inveter technology was introduced by Dalian electric motor manufacturer approved by the The National Economic commission, and became the first one in frequency inverter industry in China.In the year of 1994,Powtran inverter began to test and sell in domestic market,In the year of 2001,Dalian Powtran Technology Co.,Ltd established
Powtran PI500-S series inverter special for PV water pump adopts the high accuracy fast MPPT algorithms, tracking the PV array output by the maximum power point, driving the pump motor as much as possible to meet various pumping applications.
PI500A-S/PI500-S series solar inverter special for PV water pump adopts the high accuracy fast MPPT algorithms, tracking the PV array output by the maximum power point, driving the pump motor as much as possible to meet various pumping applications. The solar inverter special for PV water pump can support AC input besides support PV array DC input.
When the PV array can not drive the motor or does not have output, it can also accept the grid DC input or other AC motor to supply the power to meet various emergency needs. PI500A-S/PI500-S/PI150-S series solar inverter special for PV water pump provides full protection, maximizing the life of motor and pump.
 The inverter special for PV water pump can support AC input besides support PV array DC input. When the PV array can not drive the motor or does not have output, it can also acceptthe grid AC input to supply the power to meet various emergency needs.PI500-S series inverter special for PV water pump provides full protection, maximizing the life of motor and pump. 
Technique Features:
-Built-in high precision PV array maximum power point tracking MPPT algorithms
-Dry running mode monitoring, treatment
-Tank water level control
-Accept DC/AC input
-LED displays the real time situation and the parameter of system
-Based on RS485 real time remote control system
-Fast installation design, no need extra maintenance Built-in full protection and diagnostic mechanism With AC-DC automatic witching function
-Auto switch between DC and AC can be realized through auto switcher for PI500A-S and PI500-S solar inverters only.
-Built in communication function R$485
-External GPRS device optional for remote monitoring and parameter setting

1- Environmental temperature -10℃ to 50℃ Above 40℃,the capacity will decrease 3% by each 1℃.So it is not advisable to use inverter above 50℃
2-Prevent electromagnetic interference, and away from interference sources.
3- Prevent the ingress of droplets, vapor, dust, dirt, lint and metal fine powder.
4- Prevent the ingress of oil, salt and corrosive gases.
5- Avoid vibration. The maximum amplitude of less than 5.9m / s (0.6g).
6- Avoid high temperature and humidity or exposure to rain, humidity shall be less than 90% RH (non-condensing). Do not allow condensation. In the presence of corrosive gas in the space, maximum relative humidity is no more than 60%.
7- Altitude below 1000 meters
8- Never use in the dangerous environment of flammable, combustible, explosive gas, liquid or solid.
-Built-in high precision PV array maximum power point tracking
-MPPT algorithms
-Dry running mode monitoring, treatment
-Tank water level control
-Accept DC/AC input
-LED displays the real time situation and the parameter of system
-Based on RS485 real time remote control system
-Fast installation design, no need extra maintenance
-Built-in full protection and diagnostic mechanism.

Application filed:
Agriculture irrigation, grassland animal husbandry, forest irrigation, municiple water, landscape fountain, fish pond, highway greening, coastal saltworks water supply and drainage, etc.

-Effective protection function, including PV over-voltage protection, PV polarity reverse warning, auto derating against over-temperature, etc.
-Advanced MPPT algorithms: solar power tracking efficiency reaches 99%.
-Support GPRS module, which can remote monitor the VFD by using the APP.
-Automatically start or sleep only after being connected to solar panel without any parameter setting.
-Optional boost module for 2.2kW and below, to make the pump work in low voltage and reduce the cost.
-Optional cabinet product for IP54 protection level.

Input AC voltagefrequency AC Single phase 220V(-15%)~240V(+10%)
AC Three phase 220V(-15%)~240V(+10%)
AC Three phase 380V(-15%)~440V(+10%)AC 3PH 480V(-10%)~480V(+10%)
Recommend solar input
DC voltage range
G1/G2:DC 200~440V;
G3:DC 350~780V
G4:DC 450~870V
Control system High performance vector control inverter based on DSP
Control method V/F control, vector control W/O PG
Automatic torque boost function Realize low frequency (1Hz) and large output torque control underthe V/F control mode.
Acceleration/deceleration control Straight or S-curve mode. Four times available and time range is0.0~6500.0s.
V/F curve mode Linear, square root/m-th power, custom V/F curve
Over load capability G type:rated current 150% - 1 minute, rated current 180% - 2 seconds
F type:rated current 120% - 1 minute, rated current 150% - 2 seconds
Maximum frequency 1,Vector control:0~300Hz; 2,V/F control:0~3200Hz
Carrier Frequency 0.5~16kHz; automatically adjust carrier frequency according to the load characteristics.
Input frequency resolution Digital setting: 0.01Hz Analog setting: maximum frequency×0.1%
Start torque G type: 0.5Hz/150% (vector control W/O PG)
Speed range 1:100 (vector control W/O PG) 1:1000 (vector control W/ PG)
Steady-speed precision Vector control W/O PG: ≤ ± 0.5% (rated synchronous speed)
Torque response ≤ 40ms (vector control W/O PG)
Torque boost Automatic torque boost; manual torque boost(0.1%~30.0%)
DC braking DC braking frequency: 0.0Hz to max. frequency, braking time:
0.0~100.0 seconds, braking current value: 0.0%~100.0%
Jogging control Jog Frequency Range: 0.00Hz to max. frequency;
Jog Ac/deceleration time: 0.0s~6500.0s
Multi-speed operation Achieve up to 16-speed operation through the control terminal
Built-in PID Easy to realize closed-loop control system for the process control.
Automatic voltage regulation(AVR) Automatically maintain a constant output voltage when the voltage of electricity grid changes
Solar pump inverter special function Maximum light power tracking, light and weak auto sleep, light intensity automatic awakening, high water level automatic stop, low water level automatic operation, under-load protection, etc
Self-inspection of peripherals after power-on After powering on, peripheral equipment will perform safety testing, such as ground, short circuit, etc.
Quick current limiting The current limiting algorithm is used to reduce the inverter over current probability, and improve whole unit anti-interference
Timing control Timing control function: time setting range(0m~6500min)

Motor Driver Electric Specification
Nominal Power 55kw/75HP
AC Output Voltage 380
Number of Input Phases 3
Max Solar DC Voltage 800
Rated Output Current 110
Max Peak power 75Kw
Motor Driver Efficiency η 95
Communication Modbus, E-102 RS485, E-180 485
Driver Digital Input 6
Driver Analogue Input 3
Driver Digital Output 2
Driver Analogue Output 2
Number of Solar Module 550w (16x 8 )= 128 Pcs-- 450W (16x 9 )= 144 Pcs-- 400W (16x 10 )= 160 Pcs-- 385W (18x 10 )= 180 Pcs-- 340W (21x 9 )= 189 Pcs-- 285W (21x 11 )= 231 Pcs
Dimension(With X Dept x Height) 300x283x520mm
Motor Driver Mechnanical Specification
Compliance with standards CE, ISO9001,EN 61800,EN 61800, TUV, Rohs
Installation altitude -20 ... 60 °C (-4 ... 140 °F)
Inverter Weight kg Fan