Shop By Categories
Huawei 100kw SUN2000-100KTL-M1 10xMPPT Ongrid Inverter Threephase 380Volt commarcial Industrial

Huawei 100kw SUN2000-100KTL-M1 10xMPPT Ongrid Inverter Threephase 380Volt commarcial Industrial

Brand:Huawei
Product Code: Huawei SUN2000-100KTL-M1
Reward Points: 3150
SKU : Huawei 100Kw M1
Product available in stock : 1
  • 137,091.60₺

  • Ex Tax: 114,243.00₺
  • Price in reward points: 315000
  • 11 or more 127,386.00₺
  • 100 or more 121,320.00₺

Available Options


The products can be delivered from the factory, Ankara or Istanbul branch. If you are close to the branches of our company, you can check the stock in our unit close to you by contacting us by phone or e-mail.
Shippment Fee :You can order or order shipping cost. Those who cannot get cheap money from our company.
Dimension 500km 750km1000km+++
Box-Shippment1day2 day 3 day5 day
By Truck3 day 4 day 5 day
7 day
  • Easy to buy & return
  • 100% Secure Payments
  • 24x7 Support Available
  • Shop with our Application

Tags: huawei 100kw, Huawei Sun 2000-100KTL, huawei ongrid 100kw

Taksit Tutarı
Toplam Tutar
2 x 31.280,34 TL
62.560,67 TL
3 x 21.336,86 TL
64.010,59 TL
4 x 16.389,74 TL
65.558,95 TL
5 x 13.439,93 TL
67.199,63 TL
6 x 11.471,07 TL
68.826,39 TL
Taksit Tutarı
Toplam Tutar
2 x 31.314,12 TL
62.628,23 TL
3 x 21.369,88 TL
64.109,65 TL
4 x 16.426,87 TL
65.707,49 TL
5 x 13.477,40 TL
67.387,01 TL
6 x 11.512,05 TL
69.072,29 TL
Taksit Tutarı
Toplam Tutar
2 x 31.293,84 TL
62.587,68 TL
3 x 21.391,16 TL
64.173,49 TL
4 x 16.452,97 TL
65.811,87 TL
5 x 13.502,50 TL
67.512,51 TL
6 x 11.543,67 TL
69.262,00 TL
Taksit Tutarı
Toplam Tutar
2 x 31.260,11 TL
62.520,21 TL
3 x 21.322,75 TL
63.968,24 TL
4 x 16.378,63 TL
65.514,51 TL
5 x 13.430,59 TL
67.152,95 TL
6 x 11.462,90 TL
68.777,42 TL
Taksit Tutarı
Toplam Tutar
2 x 31.642,12 TL
63.284,23 TL
3 x 21.737,50 TL
65.212,50 TL
4 x 16.835,02 TL
67.340,07 TL
5 x 13.897,21 TL
69.486,04 TL
6 x 11.997,85 TL
71.987,09 TL
Taksit Tutarı
Toplam Tutar
2 x 31.508,04 TL
63.016,08 TL
3 x 21.500,59 TL
64.501,78 TL
4 x 16.516,69 TL
66.066,75 TL
5 x 13.532,43 TL
67.662,16 TL
6 x 11.547,80 TL
69.286,82 TL
Taksit Tutarı
Toplam Tutar
2 x 31.628,32 TL
63.256,63 TL
3 x 21.635,33 TL
64.906,00 TL
4 x 16.674,33 TL
66.697,33 TL
5 x 13.742,45 TL
68.712,24 TL
6 x 11.761,37 TL
70.568,20 TL
Taksit Tutarı
Toplam Tutar
2 x 31.239,90 TL
62.479,80 TL
3 x 21.313,34 TL
63.940,03 TL
4 x 16.380,48 TL
65.521,92 TL
5 x 13.433,70 TL
67.168,50 TL
6 x 11.471,07 TL
68.826,39 TL
Taksit Tutarı
Toplam Tutar
2 x 31.341,19 TL
62.682,37 TL
3 x 21.407,74 TL
64.223,23 TL
4 x 16.467,92 TL
65.871,66 TL
5 x 13.497,79 TL
67.488,95 TL
6 x 11.529,90 TL
69.179,39 TL
  • Prior to installing modules please obtain information about any requirements and necessary approvals for the site, installation and inspection from the relevant authorities.

    SAFETY INSTRUCTIONS

    WARNING: This chapter contains important safety and operating instructions. Read and keep this manual for future reference.

    1. Before using the unit, read all instructions and cautionary markings on the unit, the batteries and all appropriate sections of this manual.

    2. CAUTION --To reduce risk of injury, charge only deep-cycle lead acid type rechargeable batteries. Other types of batteries may burst, causing personal injury and damage.

    3. Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire.

    4. To reduce risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.

    5. CAUTION – Only qualified personnel can install this device with battery. 6. NEVER charge a frozen battery.

    7. For optimum operation of this inverter/charger, please follow required spec to select appropriate cable size. It’s very important to correctly operate this inverter/charger.

    8. Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool to spark or short circuit batteries or other electrical parts and could cause an explosion.

    9. Please strictly follow installation procedure when you want to disconnect AC or DC terminals. Please refer to INSTALLATION section of this manual for the details.

    10. Fuses (3 pieces of 40A, 32VDC for 1KVA, 4 pieces of 40A, 32VDC for 2KVA and 6 pieces for 3KVA, 1piece of 200A, 58VDC for 4KVA and 5KVA) are provided as over-current protection for the battery supply.

    11. GROUNDING INSTRUCTIONS -This inverter/charger should be connected to a permanent grounded wiring system. Be sure to comply with local requirements and regulation to install this inverter. 

    12. NEVER cause AC output and DC input short circuited. Do NOT connect to the mains when DC input short circuits.

    13. Warning!! Only qualified service persons are able to service this device. If errors still persist after following troubleshooting table, please send this inverter/charger back to local dealer or service center for maintenance. Maximum Panel Connection Type, Number Of module

    280W Solar Panel Minimum 1Series, Maximum 2 Series, Maximum 5 Module

    340W Solar Panel Minimum 1 Series, Maximum 2 Series, Maximum 4 Module

    400W Solar Panel Minimum 1 Series, Maximum 1 Series, Maximum 3 Module

    455Wat Solar Panel Minimum 1 Series, Maximum1 Series, Maximum 3  Module

    · Check applicable building codes to ensure that the construction or structure (roof, facade, support, etc.) can bear the module system load.

    · CS-series solar modules have been qualified for Application Class A (equivalent to Safety Class II requirements). Modules rated under this class should be used in systems operating at voltage above 50 V or power above 240 W, where general contact access is anticipated.

    · Atakale Solar Inc. modules have been certified  as Type 1 or Type 4 according to UL 1703 andClass C according to IEC 61730-2, please refer to the datasheet or the product nameplate for the detailed types.

    · Consult your local authority for guidelines and requirements for building or structural fire safety When installing modules, ensure the supporting roof has a fire resistant roof covering rated for the application. · The fire rating for this module is only valid when the product is installed as specified in the mechanical mounting instructio

    The module is intended for use in general open-air climates, as defined in IEC 60721-2-1: Classification of environmental conditions Part-2-1: Environmental conditions appearing in nature - Temperature and humidity.

    · Please consult the atakale Solar Inc. technical  support department for more information on the  use of modules in special climates, , such as an altitude greater than 2000 m.

    Exposing modules to salt (i.e. marine environments) or sulfur (i.e. sulfur sources, volcanoes) incurs the risk of module corrosion. · Do not expose modules and their   onnectors to any unauthorized chemical substances (e.g. oil, lubricant, pesticide, etc.), as modules may incur damages.

    · Failure to comply with these instructions will void atakale Solar Inc. limited warranty

    Features

     Pure sine wave inverter

    •  Built-in MPPT solar charge controller
    •  Configurable input voltage range for home appliances and personal computers via LCD setting
    •  Configurable battery charging current based on applications via LCD setting
    •  Configurable AC/Solar Charger priority via LCD setting
    •  Compatible to mains voltage or generator power
    •  Auto restart while AC is recovering
    •  Overload/ Over temperature/ short circuit protection
    •  Smart battery charger design for optimized battery performance
    •  Cold start function

    Basic System Architecture 

    The following illustration shows basic application for this inverter/charger. It also includes following devices to have a complete running system:

     Generator or Utility. 

     PV modules (option)

    Consult with your system integrator for other possible system architectures depending on your requirements. This inverter can power all kinds of appliances in home or office environment, including motor-type appliances such as tube light, fan, refrigerator and air conditioner.

    CAUTION!! Before connecting to AC input power source, please install a separate AC breaker between inverter and AC input power source. This will ensure the inverter can be securely disconnected during maintenance and fully protected from over current of AC input. The recommended spec of AC breaker is 10A for 1KVA, 20A for 2KVA, 32A for 3KVA, 40A for 4KVA and 50A for 5KVA.
    CAUTION!! There are two terminal blocks with “IN” and “OUT” markings. Please do NOT mis-connect input and output connectors. WARNING! All wiring must be performed by a qualified personnel. WARNING! It’s very important for system safety and efficient operation to use appropriate cable for AC input connection. To reduce risk of injury, please use the proper recommended cable size as below. Suggested cable requirement for AC wires
Huawie String Ongrid Inverter
Features

Benefits
1-12 MPPT Tracking MBUS&Modbus LAN ,USB Supported
The horizontal and  vertical mounting possibility
%99  Maximum Efficiency-Protected Fuse Free Design
Standard wireless access from any mobile devices
String-level Management-Surge Arresters  for DC & AC
Power module&wiring box in one compact chassis
MPPT Smart Current-Volt U/V Curve Diagnosis Supported
Remote monitoring and firmware upgrade. IP 66
Power Out
PV DC Range
Number of MPPT 
1kw-330kw
30V-2000V 
12
GTIP Custom Code :8504403090 Manufacturer  Huawei

The Huawei SUN2000-100KTL-M1 inverter boasts impressive versatility with ten MPPTs, effortlessly accommodating various layouts in three-phase, 100 kW systems. Its twenty intelligent monitoring-equipped strings ensure continuous energy production by rapidly identifying and addressing any operational concerns.
The Huawei SUN2000-100KTL-M1/M2 inverter is an uncompromisingly powerful module for large-scale solar power systems. It converts the electricity generated from sunlight into grid-standard alternating current. This is available on site or for feeding into the grid. The dimensions of 1035 x 700 x 365 mm are compact for an inverter of this power class, the weight is 90 kg. Installation is therefore best done by two or three people. The DC connection to the PV system is made via plug-in connections, so that commissioning is quickly completed. The Huawei FusionSolar app helps with the setup. The Huawei SUN2000-100KTL-M1 inverter also connects effortlessly with smart components. It supports RS485 communication, for example, with the smart logger. The data can be viewed via the FusionSolar management system.
In summary, the Huawei SUN2000-100KTL-M1/M2 inverter offers numerous advantages, including the module already has overvoltage protection (type 2 for DC and AC). In addition, ten independent MPP trackers are installed at the factory. Another pleasant feature is the low noise level thanks to modern active cooling. The output of 110,000 watts corresponds to the needs of a large system, the MPPT voltage range is between 200 and 1000 volts. The maximum efficiency reaches an astonishing 98.8 percent, the European efficiency 98.6 percent. All this ensures a high yield during operation.
Sun 2000-100KTL-M0/M1/M2 comparasion

Sun 2000-100KTL-M0

Max Efficency :98.6%

Max. Current per MPPT:26A

Number of MPP Trackers :10

Arc Fault Protection : No

Ripple Receiver Control : No

Integrated PID Recovery :No

Comm: 

90Kg

Sun 2000-100KTL-M1

Max Efficency :98.8%

Max. Current per MPPT:26A

Number of MPP Trackers :10

Arc Fault Protection : Yes

Ripple Receiver Control : Yes

Integrated PID Recovery :Yes

Comm: WAN, Ethernet, Wifi, 4G

93kg

Sun 2000-100KTL-M2

Max Efficency :98.8%

Max. Current per MPPT:30A

Number of MPP Trackers :10

Arc Fault Protection : Yes

Ripple Receiver Control : Yes

Integrated PID Recovery :Yes

Comm: WAN, Ethernet, Wifi, 4G

93kg


This document describes the following inverter models (also referred to as SUN2000) in terms of the safety precautions, product introduction, installation, electrical connections, power-on and commissioning, maintenance, and technical specifications. Read this document carefully before installing and operating the inverter.
The Huawei SUN2000-100KTL-M1 is the smart and powerful three-phase string inverter for commercial applications. Equipped with an AI-supported arc protection function, damage caused by potential electrical hazards is reduced or prevented. With built-in communication capabilities such as Bluetooth RS 485 and communication support, the installed system can be easily monitored remotely. Four maximum power point trackers (MPP) ensure precise recording of the maximum available energy of the solar modules, even in changing light conditions. Thanks to its compact dimensions and low weight of just 93 kg, it is also quick and easy to install. With IP65 protection, the SUN2000-110KTL-M0 is both dustproof and waterproof, making it suitable for outdoor installation.
Features:
-More safety thanks to active AI-supported arc protection
-Integrated AC & DC surge protection (TypeII)
-Fanless design for quiet and trouble-free operation 
-Compatible with all new Huawei power optimizers
-Supported connections via WLAN, Fast Ethernet and 4G supported
Huawei Technologies Co., Ltd.
Huawei is a leading global technology company headquartered in China. With an impressive presence in over 170 countries, Huawei has made a name for itself in various industries, including telecommunications, information technology, and renewable energy. In its solar division, Huawei develops and manufactures cutting-edge solutions for the photovoltaic industry. The company offers a wide range of products, including inverters, intelligent PV controllers, and a proprietary plant monitoring management platform called FusionSolar. With a strong focus on innovation, sustainability, and quality, Huawei has established itself as a strong player in the solar industry. The company is driving the development of renewable energy technologies, contributing to the creation of a sustainable energy future.
Key Features of the Huawei SUN 2000-100KTL-M1
-Has maximum efficiency of 98.6%, ensures maxenergy is converted into usable electricity.
-The inverter uses advanced power conversion technology to ensure maximum energy yield and long-term stability.
-Three-phase output, which is ideal for large-scale PV systems and provides a more stable and reliable power output.
-Compact and lightweight design & easy to install and transport.
-Durable, and Reliable performance
-User-friendly design and easy-to-replace components, making maintenance quick and simple.
-Remotely monitored and managed using Huawei’s SUN2000 Monitoring and Management System

Huawei SUN2000-100KTL 100kW 3phase Solar Inverter
Huawei's new SUN2000-100 KTL-M1 is an inverter that combines several advantages and features, presenting itself as an innovative product that adapts to the customer's needs. The main features on which this product is based are efficiency, safety, reliability and much more.The Huawei SUN2000-100 KTL-M1 3phase Solar Inverter series of products uses three-level circuit topology, the maximum efficiency up to 98.6%, Photon test result is A+/A+ at both of high irradiation and medium irradiation. The six MPPT is adaptable and flexible for building roof-top PV plant design to improve system yields. DC&AC lightning protection module integrated and natural cooling effectively improve product reliability.This Huawei SUN2000-100 KTL-M2 3phase Solar Inverter has good environment adaptability and can be used for various scenarios covering from 121kW to Megawatts, either rooftop or ground mounted power plants. This Huawei inverter, SUN2000-100 KTL-M1, has many other features and advantages, clearly described in the technical data sheet that can be downloaded from the VPSolar website, where you can also find the complete Huawei catalogue and request your offer.
-Smart 6 MPPTs for versatile adoptions to different layouts
-12 strings intelligent monitoring and fast trouble-shooting
-Power Line Communication (PLC) supported
-Smart String I-V Diagnosis supported
- The maximuminput voltage is the upperlimit of the DC voltage. Any higherinput DC voltage wouldprobably damage inverter.
- Any DC input voltage beyond the operating voltage range may result in inverterimproper operating.
- SUN2000-30~100KTL-M1 raises potential between PV- and ground to above zero throughintegrated PID recovery functionto recover moduledegradation from PID. Supported module types include:P-type (mono, poly),N-type (nPERT, HIT)
-Preliminary version. For Reference only. Any datasheet issued previously becomes invalid when the official version is released.
-The words and pictures in this release only reflect the preliminary status of the products and solutions. Because of the product development, the technical specifications from this version may change. We

Huawei Ongrid Inverter Protection
-Input-side Disconnection Device
-Anti-islanding Protection 
-AC Overcurrent Protection
-DC Reverse-polarity Protection 
-PV-array String Fault Monitoring 
-DC Surge Arrester Type II
-AC Surge Arrester Type II
-DC Insulation Resistance Detection 
-Residual Current Monitoring Unit 
-Arc Fault Protection 
-Ripple Receiver Control
I-ntegrated PID Recovery

Inverter Electrical Features
Inverter Rated Power (Wat) 100000
Maximum PV Input Power (Wat) 110000
PV Start Voltage (DC Volt) 200
PV Max Voltage (DC Volt) 1100
Max Operation Voltage (DC Volt) 1000
Max Surge Power (Wat/VA) 110000
Inverter Type Ongrid
Technology Transformerless
Battery Voltage (DC Volt) 0
Grid Voltage-Volt 380
Number of Phase 3
Frequency Range 50 Hz/60 Hz (Auto sensing)
Solar Charge Type MPPT
Solar Charge Current(DC Amper) 0
Grid Charge Current(DC Amper) 0
Inverter Efficiency % 98.80
Inverter Displays LED indicators; WLAN adaptor + FusionSolar APP
İnverter Communications LED Indicators, Bluetooth/WLAN + APP USBB
Number of MPPT 10
Number of String 20
Grid Transfer Switch msecond 0
Power Consumption (wat/h) 65
Standby Power Consumption (Wat/h) 3.5
Number of Parallel 100
Inverter Protection Input-side Disconnection Device, Anti-islanding Protection , AC Overcurrent ,Protection ,DC Reverse-polarity Protection , PV-array String Fault Monitoring , DC Surge Arrester Type II , AC Surge Arrester Type II ,DC Insulation Resistance Detection , Residual Current Monitoring Unit ,
Origin China
Mechanical Features
Inverter Dimension mm/ inch 1035 x 7000 x 365 mm
Inverter Weight kg 93
Inverter Mounting Wall
Operating Enviroment
Max Operation Temperature ºC/ºF 60
Min Operation Temperature ºC/ºF -25
Cooling Air
Humidity % 100
Certificates Warranty
Certificates EN/IEC 62109-1, EN/IEC 62109-2, IEC 62116 AS/NZS 4777.2 2020
Warranty Years 5

Write a review

Note: HTML is not translated!
    Bad           Good
Captcha
Whatsapp Whatsapp Whatsapp Whatsapp